Ricoh MP2501SP Replacement Controller Board SC995-03

Visitor 337 0
MP2001L_2501L_2001SP_2501SP_1813L_2013L
Symptoms:
MP2501SP the controller board is damaged, SC995-03 after replacing the controller.                                    

Analysis reasons:
Check the SC995-03 CPM setting error in another model manual 3 Compare the machine serial number (11 digits) with the machine identification code.

Detailed information:
The machine identification code cannot be recognized due to incorrect or faulty controller replacement.
The machine serial number (11 digits) or machine identification code does not match.
Replace with a compatible controller.

Measures:
1. After replacing the controller board, the NVRAM of the original machine is used, and the BCU, EEPROM and NVRAM machine number information of the machine are consistent.
2. The controller is removed from another intact MP2501SP, which can eliminate the mismatch of the controller.
3. Check that the SP5807 machine destination is set to "China", which meets the setting requirements. For the SP5907 plug-and-play device, the manufacturer/model name displayed is “MP2501SP,” and the settings are also correct.
4. Since no SP item for changing the model code was found in the SP mode, the NVRAM of another machine was replaced, EEPROM was changed, and the serial number of BCU machine was tested, and the machine returned to normal. Determine that the NVROM is damaged or that the settings cannot be changed, causing some information to not match.
Solution
Replace the NVROM Troubleshooting.

Tags: #NVROM #SC995 #2501L #2001SP #2001L