Ricoh 831082108110 appears with code sc682

Visitor 359 0
  • 682-01: CUU: ID chip communication error (K_invalid device ID)
  • 682-06: PCU: ID chip communication error (K-channel error (e.g. bus disconnection))
  • 682-11: PCU: ID chip communication error (K-device error (no ID chip))
  • 682-16: PCU: ID chip communication error (K0 communication aborted (error during communication))
  • 682-21: PCU: ID chip communication error (K-communication timeout)
  • 682-26: PCU: ID chip communication error (K_device stop (logic stop))
  • 682-31: PCU: ID chip communication error (the buffer requested by K1 is full)
  • 682-36: PCU: ID chip communication error (with no error code)

Error situation
The CPU of BiCU detects communication errors with the TD sensor.

main reason
1. The PCU drawer settings are incorrect.
2. Damaged wires or grounding issues. Or the connection is incorrect.
3. Poor TD sensor (SEN1).
4. Poor IOB.
5. BiCU is defective.

Solution
1. Check the PCU drawer. Clean the drawer and then reposition it.
2. Reconnect the wires between the TD sensor and the PCU drawer, between the PCU drawer and IOB, and between IOB and BiCU. Or replace the wires.
3. Replace the TD sensor (SEN1).
4. Replace IOB.
5. Replace BiCU.
6. It is still necessary to check the drum developing unit, and it is recommended to replace it directly for testing.

Tags: #682 #8310 #8210 #8110