The machine uses SPDF document feeder to scan double-sided original documents in color, and there is a fault with yellow background on the back. The front is normal Reason 1) The SPDF reverse scanning head CIS of the machine is defective. 2) The SPDF reverse scanning head CIS harness of the machine is defective. 3) Problem with the scanning function settings of the machine. 4) The control board of the machine is faulty. Maintenance process 1) Check the wiring harness of the SPDF reverse scanning head on the machine and disassemble the controller board. The fault cannot be eliminated by starting the machine for detection. 2) Replace the controller board and SPDF reverse scanning head, but the fault still exists. 3) Complete scanning interface - select full-color scanning - click on automatic density, use SPDF to scan both sides normally. Troubleshooting. (Note: Full color scanning defaults to automatic density: Select full-color scanning - click on automatic density - call the programming change program - as default programming - programming - yes. Each time the customer uses full-color scanning, it defaults to automatic density.) Change scanner characteristics - scan settings - ADS background density - change to the lightest or there is a faint yellow background fault. Solution Full color scanning defaults to automatic concentration, and when using SPDF double-sided scanning, there is no yellow background fault on the reverse side, indicating normal operation of the machine. |
Tags: #c4500 #adf #Scan #CIS #Controller board