Ricoh 8210 channel error code SC401-01, light color

Visitor 347 0
8210, recently frequently reported error 401-01, the image density is very light. The carrier and drum core were replaced, and after executing 3-030, the gamma value of 3-630 was too low, 0.58. After several forced powder refills, the image density changed and became deeper, with a value of 0.96 for 3-630. However, after printing thousands of sheets continuously, the density would decrease again, reporting 401-01. Later, it was suspected that there was a blockage in the pipeline between the powder bottle and the developing chamber. Normal forced powder refilling was carried out twice, and the concentration was already very deep. Previously, forced powder refilling was done 5-6 times, but the concentration was not very deep. The powder supply unit was removed, and the powder hopper was taken out to pour out the powder. The pipeline was cleaned, and then the machine was installed and forced. Supplement powder, execute 3-030, 3-011, refresh the photoelectric conductor, 3-630 value 1.01, normal concentration, continuous printing without reporting faults, fault resolved

Tags: #SC401-01 #Light color #8210 #Powder unit