Ricoh MP8001 boot can not enter the ready state

Visitor 348 0
After turning on an Aficio MP8001, it cannot enter standby mode. The panel can select paper boxes and other copying functions, but it cannot copy and there is no sound of process control.

Reason
Analysis process:
1) Enter maintenance mode and observe SP1-106-1 and 2 (fixing temperature display). The temperature in the middle and at both ends can reach and maintain normal standby temperature;
2) Observe the readings of the ID sensor and TD sensor, both within the normal range;
3) Observing SP7-403, there are no SC records related to process control and drum potential errors. Only SC182 occurred once 2 months ago (the faulty fan has been replaced);
4) From the above phenomenon, it can be concluded that the preheating and process control of the fixing are normal. So, is the problem due to some data loading process during startup? For example, hard disk data.

Solution
After performing SP5-832-1 (hard disk formatting), troubleshoot.

Tags: #hard disk #8001 #Ready #9001

Leave a comment