Analysis process: 1 Execute the print SP1-103-2, print the test sample, the sample is abnormal. 2. Execution of the quick line position adjustment failed. Running SP2-111-3 and -1 again still results in failure. 3. Check the SP2-194-10-13 and the display result is "5" (the sampling data is out of the correction range). 4. Confirm that the four-color PCDU and the image transfer belt are normal by observing the print sample. 5. Replace the laser unit test, the fault remains, and the line position adjustment result is still "5". 6. After using SP5-824 to back up NVRAM data, execute SP5-801-1, execute SP2-111-3 and -1 again to display success, print test sample diagram is normal, and the fault is solved. Solution:Perform SP5-801-1, re-perform line position adjustment and troubleshooting. Note: Be careful when performing SP5-801. Be sure to use SD card to back up NVRAM data before doing so. |
Tags: #Double image #C3500 #Laser Unit