Ricoh IMC3500 panel prompts "restart"

Visitor 279 0
Symptoms:
After the new machine is installed, the panel prompts "restart" with the specific message: "A functional problem has occurred. Press [restart] after the current process is over. Please repeat the settings after the machine restarts." See the figure below:
Analysis reasons:
1, check SMC, check the SC code for nearly 10 times, no exception;
2, click "restart" to restart, failed to solve;
3. Check the connection between the controller and BICU and the wiring harness of BICU. No abnormality is found;
4. Check the hard disk connection and find no abnormality;
5. Check the wiring harness connection of imaging IOB, and no abnormality is found;
6. Check the harness connection of the high-voltage power supply board (HVP-TTS), and find that the CN802 connector is not firmly inserted;
Link: https://pan.baidu.com/s/1E4UCgMiBJNkmOnRBinGjpQ
Extraction Code: 6uzo
After copying this content, open Baidu's internet disk mobile phone App, which is more convenient to operate.
7. Reconnect the harness CN802 connector of the high-voltage power board (HVP-TTS), restart the machine, and the machine works normally!
Solution:
Reconnect the harness connector (HVP-TTS) of the HV power supply board (CN802).

Note:
When the machine is turned on, it will prompt "restart". In the absence of software installation, first consider the connection of the board card and the connection between the wire harness and the board card. Especially for machines that have been disassembled and tested, when reinstalling the board card, be sure to make sure that each harness connector is firmly plugged.

Tags: #High voltage power supply board #BICU #Restart #c3500 #c2000