Ricoh SPC352DN machine boot display SC641-04 code

Visitor 345 0
A SPC352DN machine shows SC641-04 when it starts up, and the fault persists even after replacing the controller board and engine board with a new one.

Reason:
Communication error between BCU and controller board
After BCU attempted to communicate three times, the controller board did not respond.
SC641-04: UART error
Controller board software error, connection error between BCU and controller board, engine board software error.

Maintenance process:
On site inspection of the connection between the controller board and BCU confirmed that the wiring harness was normal. After replacing the BCU and controller board separately, the fault persisted. After upgrading the firmware and replacing the NVROMM chip, the fault persisted. By checking the connection wire CN307 on the CU board and connecting it to the power board, disassembling the power board and carefully inspecting it, it was found that the filtering capacitor on the power board had obvious protrusions, indicating that it was a power board fault. (See the figure below)


Tags: #C352 #641-04 #Controller #Power board