Symptoms MP9003 shows SC954. Maintenance process 1. The machine displays the SC954 fault code, and restarting the machine is ineffective. Upon checking the maintenance manual, no relevant explanation for the fault code was found; 2. Check the RTB of this series of models and find relevant instructions in RD223031;
According to the RTB instructions, SC954 did not receive the relevant settings sent by BiCU during the image processing process; 4. The fault was caused by a software defect and belongs to D-level code. However, due to restarting the machine, the code could not be cleared. According to the fault description, the BiCU board was replaced for testing and the fault was resolved. |