Symptoms: There are vertical black lines on the machine copies and printed copies, and the positions of the black lines are not fixed but close. Analyze the reasons for the vertical black line: 1. The charging and transfer components are dirty. 2. Poor development chamber components. 3. Poor charging high voltage plate and transfer high voltage plate. Measures: 1. Clean the charging and transfer components, but the malfunction persists. 2. Check that there are no abnormalities in the developing chamber. 3. After replacing the charging (developing) high-voltage board and troubleshooting, the original high-voltage board of the machine was reinstalled and measured with an electric meter. It was found that the output voltage of the high-voltage board to the developing bias during copying and printing immediately decreased after reaching -650 volts, which could not maintain the required output time of -650 volts for normal copying and printing of the machine (machine SP2201 sets the output voltage of the developing bias to -650 volts), affecting the effect of copying and printing. Solution: Replace the charging (developing) high-voltage board. |
Tags: #W3600 #W2400 #High pressure plate #Charging #Developing