Ricoh IMC3000 photocopies have grid lines

Visitor 357 0
Symptoms
1. One IMC3000 photocopy has grid lines, and the printed product is normal;

Possible causes:
Operation error/ICU malfunction

Maintenance process
1. Check the fault sample image, which is highly suspected to be a feature of the sample image output by the machine using the copy interface in SP mode. It is recommended to restart the machine and copy the test again, as the fault still persists during the copy test;
2. Test whether there are any malfunctions in the machine's printing job, and ensure that the print output is normal;
3. Power off and restart the machine (shut down, unplug, discharge), then turn it back on again, and the copied images are normal;
4. According to communication, the day before the machine malfunctioned, CE had come to the site for maintenance and then entered SP mode for parameter adjustment, but it is unknown what caused this phenomenon. Due to the fact that the Ricoh IMC machine still has 5V power supply in the circuit after shutdown to ensure that the machine can start quickly, the machine circuit was not restarted during normal power on and off. After power off and restart, the machine was restored;

Solution
Fault repair after machine power failure and restart;

Tags: #C3000 #Grid lines #c2000 #BICU

Leave a comment