Ricoh Ri100 Display SC20400

Visitor 295 0
Symptoms
Ri100 displays SC20400, shutdown.
Cause analysis
1. Regarding the code interpretation of SC20400, please refer to Figure (1)


2. After turning off the power, within a short period of time (within 30 minutes), this code cannot be eliminated when turned on.
3. After turning off the power for a long time (more than 30 minutes), this code will automatically disappear when turned on.
Based on the above analysis, the machine operates continuously in a high temperature environment, and the display of this code is due to a malfunction caused by excessive machine temperature. After the machine cools down, it can still continue to work.
Solution
After this code occurs, a delay judgment is required. After waiting for the machine to cool down, refer to the table in Figure (1) for the next step of judgment. If the code is eliminated after the machine cools down, there is no need to replace the parts.
Note
Try to avoid continuous operation of the machine in high temperature environments as much as possible; The above 30 minutes are only used as a reference time for heat dissipation, and the specific situation depends on the actual usage environment.

Tags: #20400 #100 #Ri100 #high temperature