Maintenance process: 1. After re plugging and unplugging the controller board, it can be turned on. After using it for a period of time, the fault reoccurs. 2. Check the last 10 SC code records of SP7-403, and no SC codes have appeared. 3. Upgrading the machine firmware and plugging and unplugging the wiring on the power board still result in malfunctions. 4. Replace the controller board for testing, but the fault persists. 5. Replace the power board for testing and solve the problem. Continuous testing for 20 days did not result in the above-mentioned faults. |