Troubleshooting process: When reporting this error, do not rush to blindly replace spare parts. It is important to have a clear troubleshooting approach and identify the problem before replacing the spare parts. 2. Spare parts related to this error: flat data cable connecting the laser to the DC board, connection cable providing voltage to the laser motor, DC board, laser related. Due to the large number of related spare parts, in order to find the fault point, it is necessary to eliminate each spare part one by one. 3. Methods for excluding related spare parts 1) The cables and power cables can be checked for good condition using a multimeter. If the flat wire has oxidized gold fingers, they can be cut 1-2 millimeters with scissors. 2) Due to the fact that this machine has two lasers, the quality of the lasers can be determined through cross laser testing to determine if the lasers are faulty. If there is no problem with the laser test, it is that the DC board is broken. 3) The judgment of the quality of the laser scanning motor can be done by testing the laser motor in the fault diagnosis menu, testing whether the laser motors of CMYK four colors rotate normally during the test. After testing, it was found that the motors of Y and M do not rotate. During the laser replacement test, it was found that the laser was faulty. After replacing the laser with a new one, when printing the diagnostic page to check the printing effect, it was found that the corner lines were not aligned correctly. A cold rest was performed to solve the problem. |
Tags: #M551N #M551DN #M551 #Flat cable #Laser