HP E72535 Print Boot Report Out Slot 1 Full, Machine Installed Built-in Stack

Visitor 326 0
Fault Description:
Power on self-test reports that paper slot 1 is full, and the machine is installed with a built-in stack

Resolution process:
Due to the installation of a built-in stack on the machine, it was found that the paper outlet sensor had been removed and there were no paper jams inside the stack. The stack self-test was normal when turned on, but when the stack was finally opened, it was found that the paper slot sensor sometimes could not be reset
[kkpay=3]


The sensor on the picture cannot be reset


[/kkpay]

The force of the reset spring is not sufficient. After cutting off one circle, manual testing can reset it normally, and then the installation test is normal.

You should first carefully check whether the paper outlet sensor of the machine has been removed, whether the stack paper tray can move normally, and then check whether the paper slot sensor can be reset normally.

Tags: #E72535 #Paper slot 1 is full #internal stack