Fault Description: Customer reported M126A startup error E8, the machine cannot be ready. Resolution process: Power on, printer error E8 connected to computer to print test page, normal. Based on the error code, it is determined that the scanning head is faulty, and further operation is required to remove the scanning panel. Replace it with a printer of the same model that has no faults and test the scanning panel. Everything is normal. Consider continuing to replace and troubleshoot the interface board for faults. Dismantle the interface board of the same model printer without any faults for replacement testing, and the fault persists. Reorganizing the thinking, considering that if the test page can be printed online to prove that the mechanical part of the printer is not faulty, only the power board has not been replaced for testing. Therefore, we continued to remove the power board of the same model printer without any faults for replacement testing. The test results showed that the printer displayed normally, so we can proceed with troubleshooting. Share summary: Generally speaking, if you can connect to a computer to print out the test page, you can determine that there is no malfunction in the mechanical part of the printer. Due to error codes causing judgment errors, if there are models of the same model, priority should be given to conducting replacement testing to accurately identify the fault point. In future detection operations, minimizing testing is also a very good method, which can achieve twice the result with half the effort in identifying faults and finding faulty spare parts. |
Tags: #M126A #M126 #E8 #Online printing #Scan Panel