Product Model:C1000P、C800P Topic: 045-382 PH_2 MD PWB Fuse Fail Fault phenomenon: Tray 2 Failure or Tray Empty Issue is displayed in the UI after the Tray2 tray is pushed in. Failure causes and solutions: After pushing Tray 2, the UI will show Tray 2 fault or Tray Empty problem. Check and find that F18 on PH2 MD PWB is burnt out. F18 will still be burnt out after replacing with a new MD PWB. Since the manual BSD diagram indication is not clear, you need to look at all the BSD diagrams associated with the tray to find that BSD CH1.41, CH7.20, CH7.18, and CH7.17 indicate 24V to be supplied to the Nudger Solenoid, Front Blower Fan, Rear Blower Fan, Lead Blower Fan, and End Blower Fan on the PH2 MD PWB. Through measurement and inspection, it is found that the abnormality of Tary 2 Lead Blower Fan and End Blower Fan causes F18 damage. The problem is solved after replacing Tary 2 Lead Blower Fan and End Blower Fan and replacing F18 with 5 ohm resistor to repair PH2 MD PWB.Link: https://pan.baidu.com/s/11GYlen2O4QE7r3BvEeONyQ Extraction code: 743f After copying this content, open Baidu's internet disk mobile phone App, which is more convenient to operate. |
343
0
Address of this article:https://073868.com/post/2619.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleXerox C800 C1000 Machine Report 77-134 Paper Card Code