Ke Mei C754e reported fault code C1103

Visitor 336 0
Kemei C 754e reports fault code C1103

Machine usage situation
Model: bizhub C754e

Print run: 800000
Paper Discharge Processor Model: FS-535

Fault phenomenon
When the machine outputs multiple sheets, there is a paper jam and a C1103 fault code is reported.

Fault condition
1. A4 single sheet output is normal.
2. A4 long edge paper output exceeds 9 pages, machine jams and fault code C1103 appears.
3. About 2/3 of the paper is discharged from the upper part of the paper outlet, and the alignment part of the paper outlet of the paper discharge processor has a tapping action, but it is no longer in its original position.




Troubleshooting
1. The fault code is level B. The front door was opened and closed, and the code was eliminated. The test did not resolve the fault.
Considering the high usage and long installation time of the machine, it is necessary to thoroughly clean and inspect FS-535; Disassemble the FS-535 alignment part, swap the PS17 sensor, clean the alignment part guide rod, but the fault cannot be resolved. The malfunction is not related to PS17.
3. After testing the position of the alignment motor M11/front and motor M12/rear, the fault still persists. The fault is not related to M11.
4. Checked the alignment section to the FSCB connection line and no abnormalities were found. Eliminate circuit faults.
5. There are two FS535s at the customer's site, which were tested on the alignment part and the fault still persists. Eliminate the malfunction of the alignment component.
6. During the FSCB test of FS535, the fault persisted. Eliminate FSCB malfunction.
7. Upgrade the host firmware and FS firmware, but the fault persists. Eliminate system control faults.
8. Swap FS535 test and confirm that the fault is still on FS535.
9. Suspected that the timing of the paper rolling in front of the alignment part driven by the stacker conveyor motor M10 was abnormal. After replacement testing, the fault still persists.





Case Summary
1. This fault inspection involves many components of the machine. From locking the fault code to troubleshooting each component, following the instructions in the maintenance manual, the wiring and control board were eliminated. Then, the fault was gradually detected to the surrounding components, and it was speculated that the cause of the fault may be more than one point
2. This type of machine malfunction requires technicians to spend a lot of time, be careful, and patient in troubleshooting. For difficult malfunctions, it is recommended to refer to the maintenance manual. Understanding the working principle of the machine can help analyze the cause of the malfunction.

Tags: #C754e #C1103 #Ke Mei