After replacing MFPB, the Kemei B758 keeps reporting code C-6756

Visitor 330 0
After replacing MFPB, the Kemei B758 keeps reporting code C-6756

Model
Bizhub 758 series


Fault phenomenon
After repairing other faults and reinstalling the MFPB board, the machine reported a C-6756 code and the exposure light remained on.


on-site situation
According to customer feedback, the machine is reporting C-3737 code, indicating abnormal heating temperature in the fixing center.
2. The technician confirmed at the customer site that the fixing process was normal and the issue was not resolved, so they suspect it to be a problem between MFPB boards.
3. Disassemble the motherboard of the faulty machine and test it on a normal machine. The fault did not occur on the normal machine, so it is ruled out to be an MFPB board fault.
4. The technician adjusted the fixed temperature sensor and solved the C-3737 malfunction.
5. After the fault of abnormal fixing temperature is resolved, C-6756 is reported every time the machine is turned on.








Tags: #C-6756 #758 #MFPB #C-3737

Leave a comment