Xerox C1000P/C800P out code 045-379

Visitor 319 0
Product Model: C1000P/C800P
Topic: 045-379
Fault phenomenon:
The machine may report error 045-379 at any time during printing or in Standby mode.
Cause of the failure:
The fault code means that a specific 24V fuse is burnt out. Fuse on FSR 1 MD board, swapping 1 MD and 2MD boards does not transfer the fault. Excluding the issue with Fuse itself, the target shifts to 24V power supply. Check the relevant circuit diagram and troubleshoot each section in the 24V direction. Finally, it was determined that the poor contact was caused by the Interlock (PL7.15 Item 5) of the fixing drawer.
Solution:
Replace the interlock.
The emergency solution is to connect this interlock with another control logic signal
Swap Interlock (PL7.15 Item 4).

Tags: #Xerox #C800 #C1000 #045-379 #Fault code