Fault Description: Power on normally without any errors. Error C-2733 during printing Cause of the failure: HV3 high voltage board abnormality Solution: 1. The startup is normal, but there is an error C-2733 when printing. 2. Swapping the photosensitive drum is ineffective. Removing the high-voltage disinfection wire next to the photosensitive drum can print several sheets, but the gamma error cannot pass. 3. IO check 03-15 is 1, and normal IO check 03-15 is 0. Therefore, it is determined that the HV-3 high-voltage board is abnormal, and replacing the HV-3 high-voltage board is normal.
HV-3 part number: A1RFM40500. |
Tags: #C-2733 #C1085 #Photosensitive drum #High pressure plate #Ke Mei