Ke Mei C1085 Print Period Report C- 2733

Visitor 320 0
Fault Description:
Power on normally without any errors. Error C-2733 during printing

Cause of the failure:
HV3 high voltage board abnormality

Solution:
1. The startup is normal, but there is an error C-2733 when printing.
2. Swapping the photosensitive drum is ineffective. Removing the high-voltage disinfection wire next to the photosensitive drum can print several sheets, but the gamma error cannot pass.
3. IO check 03-15 is 1, and normal IO check 03-15 is 0. Therefore, it is determined that the HV-3 high-voltage board is abnormal, and replacing the HV-3 high-voltage board is normal.


HV-3 part number: A1RFM40500.


Tags: #C-2733 #C1085 #Photosensitive drum #High pressure plate #Ke Mei