Xerox C1000P, C800P appear 091-322 CC Cleaner Motor 6 Fail

Visitor 353 0
Product model:C1000P、C800P

Topic:CC Cleaner Motor Fail!
Fault phenomenon:
91-322 CC Cleaner Motor 6 Fail occurred during IOT power on self-test.

Failure causes and solutions:
During the machine's self check upon startup, a 91-322 fault code appeared indicating a black charging and cleaning motor malfunction. Upon inspection, it was found thatOpen the front door and then turn on the device. Wait for the IOT to enter normal printing mode before running the charging components of other colors to clearThe cleaning action may also result in charging and cleaning motor faults corresponding to the color. Such as 91-321, 91-320, and 91-
319 code. Measure the 24V of CC Interlock switch up to BGM Interlock switch according to BSDVoltage, the measurement result shows that the 24V at pin PJ855Y-5 of the yellow CC Interlock switch input terminal is no longer availableYes, allocate board DST 1 (IOT-L) PWB PJ1103-1 to CC Interlock in transparent color There is 24V on the PJ855T-5 pin of the switch input terminal, so it is determined that the problem lies in the transparent colorThe CC Interlock switch output to the yellow CC Interlock switch section is abnormal. Testing and adjustmentThe issue was resolved after connecting the transparent CC Interlock switch to the yellow CC Interlock switch.
(Please refer to the following diagram and manuals BSD1.7 and BSD1.23 for understanding).Link: https://pan.baidu.com/s/1z_46EwauwcPA4KXzmoldpQ
Extraction code: 59cz
After copying this content, open Baidu's internet disk mobile phone App, which is more convenient to operate.



Tags: #Xerox #800 #1000 #Fault code #091-322