iR-ADV 6275 iR-ADV 6265 iR-ADV 6255 fault phenomenon] Power-on report E000-0000 code, check ERR records found that error records appear multiple fault codes.
[Cause of the Failure] Two 24V power supply boards of the main engine power supply department are damaged. field countermeasures] After replacing 2 24V power supply boards on site, the fault is solved. Note: This problem is only for on-site reference. The development clutch, fixing assembly, DC control board and main control board 2 have been replaced in sequence on site, but the problem has not been completely solved. The problem has been solved after two 24V power boards have been replaced. |