Ke Mei B15 Boot Report Error Code EC

Visitor 321 0
Fault phenomenon:
Machine startup prompt unable to print, fault code EC

Exclusion process:
According to the maintenance manual information
1. Replace the motherboard, but the fault persists
2. Replace the high-voltage board, but the fault persists
3. Replace the fixing fan, but the fault persists
4. Replace the fixer, but the fault persists
5. Replace the main motor, but the fault persists
6. Replace the power board, but the fault persists
7. Replace the laser, but the fault persists
According to the manual information, all relevant components have been replaced, but the fault cannot be eliminated. Finally, in an accidental situation, the fault was eliminated after replacing the alignment clutch (see the following figure for the clutch)
Link: https://pan.baidu.com/s/17_OYi7qWK0M1UWpcXkNTMA
Extraction code: 1tgw

Kemei B15 printing and copying with light colors

Exclusion process:
1. Replace the drum component and powder box, but the fault persists
2. Mark the drum and powder box and observe the driving situation
3. It was found that the powder box still cannot rotate during printing and copying, while the drum component can be driven normally,
Considering that the problem lies in the driver part
4. When disassembling the main drive and checking the installation of the internal gears, it was found that the position of the gear that drives the powder box to rotate was installed incorrectly. After consulting the dealer, it was reported that this part had been disassembled during maintenance and reinstalled in the correct position, and the machine returned to normal.
(The correct gear position to drive the rotation of the powder box is shown in the following figure)

Troubleshooting:
Careful observation reveals that the positions on the left and right sides of the gear are different. Incorrect installation can cause the gear to fail to drive the toner to rotate properly, resulting in printing problems.

Summary:
This case serves as a reference. If this problem is encountered during future maintenance, it can be first determined whether the driving component can drive the powder box to rotate. If there is a problem with the driving component, the position of the gear can be checked to see if it is normal.