The Xerox C1000 machine intermittently appears 010-311,045-379 code

Visitor 328 0
Summary
Xerox C1000 and C800 machines intermittently display codes 010-311 and 045-379

Content
  • According to the 010-311 process, execute DC330 10-106 10-007 10-008 and both RefreshRoll Retract Sensor and RefreshRoll Retract Motor are working properly.
  • Every time the code 010-311 appears, there will be a loud noise when the machine is fixed. After observation, it was found that it was caused by the sudden descent of the pressure roller. Upon entering the diagnosis, it was found that there was also a code 045-379.
  • Checking the abnormal status of the BSD 1.38 P/R latch motor will generate code 045-379. Execute DC330 010-002 to repeatedly lift and lower the pressure roller of the P/R latch motor. In every 10 actions, there will be a loud noise when the pressure roller descends. Suspect the 24V power supply problem of the motor.
  • When checking BSD10.9 1.35 1.14 and repeatedly executing 010-002, it was found that CR1 and CR2 on FLY9 PWB would flash (turn off and then turn on again) when there was a loud noise. Therefore, the problem was locked to the fixing+24V interlock. After swapping the fixing+5V interlock and 24V interlock, the fault became a prompt that the fixing device was not in place.
  • Use a multimeter to measure the resistance of the interlock when conducting, and the value of the 24V interlock is 70 ohms. Normally, it should be 0 ohms.
Replace the fixing+24V interlock and resolve the issue.
principle analysis
  • The lifting and lowering of the pressure roller are both completed by the P/R latch motor. After the lifting is in place, the P/R latch motor maintains this state to prevent the pressure roller from descending due to gravity.
  • The fixing+24V interlock has a high resistance value during conduction, resulting in insufficient+24V voltage. This causes the P/R latch motor to lose power and cannot maintain the state of the pressure roller. The pressure roller rapidly descends due to gravity, causing a loud noise.
  • The machine found that the refresh roll status was incorrect when the roller was already in the lowered position, resulting in code 010-311.
  • In this fault, since the components involved in code 010-311 were confirmed to be normal, the focus of the repair should be on code 045-379 and why the pressure roller suddenly dropped.
Link: https://pan.baidu.com/s/15Jle0uokgfiRPzHCHhe6kg
Extraction code: 1y04

Tags: #010-311 #045-379 #C1000 #Fixing