Summary Start-up report fault code 010-314 Fuser Steering Position Sensor Fail Content The J985-3 pin is loose, causing the MD PWB control Fuser Belt Walk Motor to operate abnormally. Analysis 1. DC330 drive test found that Walk Motor can smoothly drive the mechanical mechanism to retract, but the drive will stop halfway during the jacking up action, so it is determined that this fault is caused by abnormal drive in one direction. 2. Check the fixing belt assembly and Fuser Belt Walk Motor drive gear, and no obstruction is found. 3. Refer to the note at the lower right corner of BSD 10.16. The measurement J458-5 and J458-1, 2, 3, and 4 are 18 ohms, which can eliminate the problem of driving the motor. 4. It extends to the J685_F1 plug on MD PWB. The J685-14 is 18 ohms with J685-7, 9 and 10, but the resistance with J685-8 is infinite. At this point, it can be determined that this fault is caused by the loss of CLOCK/B control signal. Check the plug of the middle connecting part of the wiring. It is found that the J985-3 pin is loose, which causes the wiring abnormality. After resetting and fastening the loosened third leg of J985, the rear drive returns to normal.Link: https://pan.baidu.com/s/1pDRHVWZMyDY1c8_S8bC1pg Extraction code: c7d0 |