Xerox C550 C560 prints normally after performing data complete cleaning and hard disk formatting, but the scan template cannot be updated

Visitor 333 0
Xerox C550 C560 prints normally after performing complete data removal and hard disk formatting, but the scan template cannot update the content

1. Check that the IOT IP is 100.100.100.101 and the subnet mask is 255.255.252.0

2. Print the function setting list, check the job template saving location on page 6 and find that the setting is missing

3. Enter the IP address of the server through IE and select the Xerox CentreWare at the bottom right.

4. Select the propertiesservicesnetwork scanningadvancedtemplate pool setup and enter the information shown in the following figure under this path (user name: 11111, password: x-admin)

Reason
      The scan template is saved on the server. The default IP of IOT is 100.100.100.101 and the default IP of the server is 100.100.100.102. The two are physically connected by cross-network cables.
      When this fault occurs, settings such as the scan template path are cleared. When the IOT template is updated, the path where the server stores the scan template cannot be found, resulting in the IOT unable to update to the scan template.