Xerox DC1256 startup display 'please wait for 1 minute' (s)

Visitor 354 0
Topic: Please wait for 1 minute (s) when booting up

Summary
Please wait for 1 minute (s) when turned on. The fixing lamp is not heating up

Content
J11 A4 should always be measured at 24V, which is normal. It should be adjusted to 0V. After the fuse relay is engaged, 220V can be output to the fixing device
Upon entering the diagnosis, no other fault codes were found
Tested IOT Drive PWB, IOT CPU PWB, IOT NVM PWB without any issues
Measuring the fixing temperature sensor, it was found that the overheating sensor of the pressure roller (normally 110K in TD3 refrigeration state) had an open circuit and infinite resistance value. After replacement, the fault disappeared

The fault should be:
The open circuit of the overheating sensor caused the IOT drive PWB to not provide a control signal for the fuse relay on, resulting in a lack of 220V voltage for fixing
And the system did not display the error message correctly and is in a state of feigned death

Link: https://pan.baidu.com/s/15V-SrWuohcwycVcVWmJskg
Extraction code: ve5v

Tags: #C1256 #IOT Drive PWB #Fixing #temperature sensor

Leave a comment