Fault phenomenon: Any operation will result in a warning on the panel: the operation cannot be performed and the data reception signal light (green) on the printer control panel keeps flashing. Solution: Execute Clear All NVM, execution method: 1. Enter diagnostic mode, install the up and down keys, then turn on the device. The panel will display the password and press the down key twice
2. Follow the following process to find Clear All NVM, Printer - Installation Set - Clear All NVM, and press the OK button to perform initialization 3. The machine will automatically restart. Follow the panel prompts to reset the machine. |
Tags: #M255df #This operation cannot be executed #Clear All NVM