Ricoh W2401_3601 error code SC546,SC541

Visitor 330 0
During normal operation, the MP3600 engineering unit displayed error SC546. After arriving on site and entering maintenance mode to clear the error, the unit reported error SC541 upon startup. Observation revealed that the fuser assembly rotates normally, and during the fault-clearing power-on process, the fuser lamp lights up as expected. After the preheating process, the machine displays error code SC541. According to the instructions in the maintenance manual, check the pressure roller thermistor and found that the two thermistor AW10 0053 are worn and broken. After replacement, the fault persists. After searching the maintenance manual, it was found that the machine also had a hot roller thermistor and an AW10 0087. After disassembly, it was found that the appearance was normal. Enter SP1106 to detect and find that after the SP1106-001 value reaches about 200, it drops abnormally rapidly and shows 0 at the same time, and then returns to the value after a few seconds. Disassemble the thermal roller thermistor again and use a multimeter to test. The ohm value of the new part is 0.46, and the ohm value of the old part is 1.0. Thus, it was judged that the heat roller thermistor was damaged. Fault removed after replacement. Tip: Fixing code faults must be carried out after accurately checking the relevant contents in the maintenance manual, and the fault point cannot be determined by appearance according to common sense.

Tags: #SC546 #SC541 #Fuser #3601 #W2401