| Fault phenomenon: A 2014 machine has a weak customer response. On site inspection found that the customer was printing on a computer, and there was a phenomenon of uneven brightness in the main scanning direction of the image. Process: During the copying process, the cover was opened and it was found that the image on the surface of the drum also had uneven brightness. Upon disassembling the laser component, it was discovered that there was dust on the surface of the sealed glass and dust adhered to a reflective mirror inside. After cleaning, the installation was completed for testing and printing, and the uneven brightness was normal. The overall image density also improved significantly, but there were slight white stripes on one side of the image. Check the thickness of the carrier on the surface of the magnetic roller and no abnormalities were found. Dismantle the magnetic roller and clean it back and forth with a hard piece of paper inserted into the magnetic roller and scraper. After reinstallation, the machine prints images with normal density. Analysis shows that the toner may have clumped on the surface of the magnetic scraper, affecting the magnetic roller's ability to carry toner and causing white streaks in the image. |