Symptoms SC992 (non-fixing error) Reason Firmware bug The firmware incorrectly detected the SC992-00 and should trigger the SC570 (fan error: ozone exhaust fan or controller box ozone trap fan) for the following reasons. -Ozone exhaust fan or controller box ozone collection fan overload. -due to an external substance, one of the fans is suspended, or -Connector disconnected. Solution Production line: SC570 trigger, need to correct the firmware. (To be published in February 2016) On-site: Disconnect the plug and remove foreign matter or replace the ozone exhaust fan. NOTE: Refer to the Service Manual for replacement and positioning procedures. Replacement and Adjustment> Fan and Filter
|
Tags: #SC992 #SC570 #ozone exhaust fan #C7110S #c7100