Ricoh IMC2000 Boot Transfer Belt Assembly Rattle, SC442-00 Code

Visitor 355 0
Symptoms
IMC2000 startup transfer belt has abnormal noise and SC442-00 code appears

Maintenance process
1. SC442-00 code is an ITB lifting error, which relies on the magenta powder supply motor to drive the ITB lifting. Therefore, it is suspected that the magenta storage hopper unit is blocked and affecting the motor rotation, but the disassembly and inspection of the storage hopper unit shows that it is normal;
2. The ITB contact sensor and SP5804-150 magenta powder supply motor were tested to be working properly through SP5803-29;
3. After replacing the magenta powder supply motor and transfer belt unit, the fault still persists during testing;
4. Remove the ITB contact drive gear component for inspection and find that the bracket of the drive gear has slight deformation;
5. After replacing the two drive gear brackets in the above picture, the abnormal noise has been reduced to some extent, but the SC442 code has not been eliminated yet;
6. Upon closer inspection again, it was found that the plastic cover plate of the powder bottle rack in the following picture was not fully installed after disassembly, and was not in place, fitting snugly against the main machine frame, resulting in the transfer belt unit not being fully pushed in place and unable to trigger the ITB contact sensor, causing the SC442 code;
7. After reinstalling the plastic cover plate, the transfer belt unit was completely pushed in, and the machine malfunction was completely resolved.

Solution
The malfunction was caused by the engineer's failure to correctly restore the machine components after on-site maintenance. After reinstalling the plastic cover plate, the abnormal noise and SC442-00 code were eliminated, and the machine returned to normal.
Link: https://pan.baidu.com/s/1vuKpcAnVmmZEPo3smgaDVw
Extraction code: 7c30

Tags: #442 #2000 #3500 #4500

Leave a comment