Ricoh MPC2504 (the machine only displays user tools when it is turned on, and it will automatically shut down after one minute)

Visitor 361 0
Symptoms
The machine startup screen only displays user tools, clicking on the screen does not reflect the phenomenon of user tools, and the machine automatically shuts down after one minute

Reason
Poor display screen of the machine.
The IPU board of the machine is defective.
The wiring harness connecting the machine is faulty.
The chip of the machine is faulty.
The controller board of the machine is faulty.

Maintenance process
On-site maintenance measures:
1) Check the relevant wiring harness on the machine, reinstall the machine control board and IPU board. The fault cannot be eliminated by starting the machine for detection.
2) Replace the SOP screen, IPU board, and chip of the machine. The fault still exists.
3) Replace the controller board of the machine and troubleshoot.

Solution
Replace the controller board of the machine, and the machine is functioning properly.

Tags: #2504 #chip #Controller #IPU #SOP