Symptoms Power on report code SC995-02. CPM setting error 2, machine serial number or machine identification code does not match. Reason After the expiration of the four drum cleaning, the machine was locked. After replacing the drum cleaning with a new one, the relevant items were reset in SP7622, but the drum cleaning still needs to be replaced. Perform data clearing for SP5801-002 print engine. Report a paper jam at D2 after turning on the machine. After importing the NVRAM data (sp5824) of another 5100 machine into this machine (SP5825), the machine reports the code SC995-02. Solution One Check SP5811-001, SP5811-004 is the serial number of this machine, and SP5811-005 is the serial number of another 5100 machine. These three serial numbers must be consistent to avoid reporting SC995-02, but the serial number of SP5811-005 cannot be changed on the control panel. 2、 Replace the NVRAM (part number: D1389590) on the control board. There are two NVRAMs on the control board that must be replaced at the same time. Ordering with D1389590 is a pair. When replacing, be careful not to insert M1 and M2 in the wrong position. The chip has a direction, so be careful not to insert them incorrectly when installing on the control board. SP5811-005 is the serial number of this machine when it is turned on. The device is functioning properly. Summary: After the PM parts expire and lock, reset the corresponding item in SP7622, change the corresponding item value to 0 in SP7623, and change the corresponding item value from 0 to 1 in SP3701. After restarting, the lock prompt will be eliminated. The serial number of SP5811-001 SET is stored in the EEPROM on the BCU board (part number: 14077899), and this value can be modified on the control panel. The serial number of SP5811-004 SET BCU is stored on the BCU board (part number: D1365151), and this value can be modified on the control panel. The serial number of SP5811-005 SET NOVITA is stored in the NVRAM on the controller board (with two part numbers: D1365757 for C5110s and D1365756 for C5100s) and cannot be modified on the control panel. When replacing with a new NVRAM, the machine serial number will be automatically written into the NVRAM after booting up. Therefore, before replacing with a new NVRAM, ensure that the values of SP5811-001 and SP5811-004 are consistent. 3. The NVRAM data of the device must be backed up (SP5824), which is an indispensable step in the installation process. |
Tags: #C5110s #CPM setting error 2 #SC995-02 #serial number #Control panel