Symptoms 1. One M2701 has a problem of skewed DF scanned copies, but the copying and scanning on the draft table are normal; Possible causes: DF defect/DF exposure glass defect Maintenance process 1. Upon on-site inspection of the malfunction, it was confirmed that the scanning of the manuscript table was normal. When scanning through DF, there will be an overall tilt of about 2-3mm; 2. Adjusting SP6-006-01/02/03/04 did not improve the effect; 3. Adjusting the strip glass and DF glass cover is ineffective; 4. Dismantling and reinstalling DF is ineffective; 5. Adjusting the position of the DF feed guide and reinstalling it is ineffective; 6. Adjust the fixing screws of the DF seat again, and after multiple adjustments, the fault was eliminated; Link: https://pan.baidu.com/s/1M8_en5bR6CL1yM_LqLucKg Extraction code: 781m |
Tags: #adf #Document Feeder #skew #m2701