Symptoms The main interface of MC2000 startup is normal, as shown in Figure (1), but it crashes when entering the copy interface, and pressing the touch screen and physical buttons is ineffective.
Cause analysis 1. Preliminary judgment is that there is a malfunction in the operation panel, and replacing the operation panel is ineffective. 2. Replacing the controller board and BICU board is ineffective. 3. During the inspection process, it was found that the CIS LED light did not light up when the cover sensor was triggered.
4. After replacing CIS, it returned to normal. Solution Replace the CIS scanner. Note: This model scans the parts (including CIS) inside the components, and their numbers need to be checked in the optional parts manual. |
Tags: #crash #C2000 #Controller board #BICU board #Cover plate sensor