Ricoh IM2500 cannot set scan destination from history

Visitor 343 0
SymptomsAfter firmware upgrade, it is no longer possible to set the scanning destination from the historical records。 Usage:     After upgrading the new firmware, when SP setting SP5-888-001 is enabled, even if user authentication is disabled, personal information can still be blocked, and sending history records will be blocked, and targets cannot be set from the history records.
After enabling personal information protection (SP5-888-001:1), personal information will be blocked in the history of the scanner or printer application when the user has not been authenticated. Attention: The purpose of this specification change is to correctly apply personal information masks to scanner and printer applications in accordance with the settings of SP5-888-001. Previously, regardless of the settings of SP5-888-001, disabling user authentication did not block personal information. To restore the previous behavior, please set SP5-888-001 to 0 (disabled).
SP5-888-001 setting only affects the display of personal information. Setting conditions: To make the changes to this specification effective, please set the following two settings -User authentication: disabled and - SP5-888-001 (personal information protection): 1 (enabled).The following figure shows the effect of this specification change:Link: https://pan.baidu.com/s/1b-Y_zP_n-I2hrmntQUBqyQ Extraction code: pqvv

Tags: #2500 #3500 #5000 #Scan #User authentication