C2552: Abnormally high toner concentration detected by cyan TCR sensor C2554: Magenta TCR sensor detects abnormally high toner concentration C2556: Yellow TCR sensor detects abnormally high toner concentration C2558: Black TCR sensor detects abnormally high toner concentration Related accessories: Development unit/C,M,Y,K Toner Cartridges/C,M,Y,K Front Circuit Board (FRB) Print Control Panel (PRCB) Handling method: 1 Reinstall developer unit 2 Reinstall the toner cartridge 3 Check whether the connection of the connector between the developing unit-FRB CN13,CN14,CN15,CN16,CN10 is correct, and repair if necessary 4 Check whether the connection between FRB CN1,CN3-PRCB CN7, and CN9 is correct, and repair it if necessary 5 Replace development unit 6 Replace FRB 7 Replacing the PRCB |