Konica Minolta C253/353, Code C2557 Solution

Visitor 311 0

1. fault phenomenon

Machine model: Konica Minolta C253/353

Error code: C2557, abnormal powder concentration in the black developing chamber.

Usually, an error occurs when printing/copying dozens of copies again after installing a black toner cartridge or pulling a black toner cartridge. After clearing the code, an error message appeared again shortly after use.

2、 Solution method

1. The lower powder port of the powder box is blocked, resulting in insufficient powder replenishment. The TCR sensor detects the powder concentration incorrectly. Reinstall the powder box and check the lower powder port of the powder box.

2. Poor contact of the black toner cartridge caused the TCR sensor to fail to perform normal testing. Reinstall the black toner cartridge and check the cartridge connector.

3. Forced powder replenishment can be performed in maintenance mode, and the TCR value can be observed to determine if the powder box is faulty. If the TCR value remains unchanged after mandatory powder replenishment, it indicates a powder box malfunction

4. TCR sensor malfunction, please replace with a new black drum.

3、 Explanation

This fault may also occur on blue, yellow, magenta toner cartridges or drum components, with error codes indicating abnormal powder concentration detection in the developer compartment. However, the cause of this problem is not limited to the compartment, and the inability to dispense powder from the toner cartridge is one of the more common reasons. So during maintenance, the problem points should be comprehensively identified.


Tags: #C253 #353 #C2557

Leave a comment