Konica Minolta C308/368 abnormal sound

Visitor 294 0
Today, I will share with you how to repair and solve the intermittent abnormal noise that occurs during the use of Kemei bizhubC308.Model:         BizhubC308 series abnormal noiseCause of the failure:     1. In maintenance mode ->status determination ->read inspection ->open front cover ->load inspection ->close front cover ->enter code 42-2 to check if the abnormal noise is caused by fan oscillation. If the check is confirmed, follow the instructions shown in the following figure.

Abnormal noise location:Cooling fan for transfer belt on the left side of the yellow developing chamber (indicated in the above picture)


Fixed position:A screw behind the power board on the left side of the machine is fixed, causing it to be loosely secured

Fault solution:1. Remove the entire fan assembly from the machine and paste a sponge at the location indicated in the picture to reduce vibration, resolving the issue.2. Part number: A161140200.3. The fault has been reported to the manufacturer and no improvement part number has been released yet. If there are any improvement parts, a new part number will be released in a timely manner.