Ke Mei 283, 363 and 423 operation panels did not respond.

Visitor 309 0
[Symptom] The machine starts up, and the control panel surface appears normal. When you select any function or operation on the control panel button or touchscreen, the machine does not respond. NVRAM cannot be repaired due to unresponsive touch screen

[Cause] The memory module on the PWB-MFP may be faulty or the operator panel may be faulty.

Solution: Use the memory module to verify the operation of the machine (from top to bottom and then from bottom to top). If the machine is turned on and the display is normal, the memory function is good. If the LCD on the operator panel is blank after booting, replace both memory modules. If it is not normal, the operation panel may need to be replaced. bizhub 223/283/363/423 (PC4300,533Mhz,DDR2),V865300026