Canon MF621 tips E840 error

Visitor 349 0
Processing procedure:
1. There is no sound when starting up, and an error E840 is reported. It is necessary to judge whether the fixing drive assembly is working normally.
2. Determine whether the fixing drive assembly is working normally, and whether the power supply is normal, etc.
3. The fixing motor is controlled by the drive circuit board
4. The drive circuit board is powered by the low-voltage power supply board. The 24V supply of the measurement drive circuit board is normal, and the main motor also has 24V input
5. Measure the voltage supplied by the low-voltage power supply board to the DC control circuit board, which is normal
6. It is more likely to infer the drive circuit board.
7. Replace the drive circuit board to solve the fault



Tags: #MF621 #E840 wrong