How to deal with the error fault code of bh287 copier C- 5370?

Visitor 257 0
Model: Konica Minolta bizhub287 fault phenomenon: the code "C-5370" is reported when the power is turned on, and the switching power supply cannot clear the fault code (1) content fault type: C5370 power supply cooling fan cannot rotate level: c, fault detection condition: during fan rotation, the fan lock signal remains at high level within a predetermined continuous time interval. related electrical parts: power supply cooling fan (FM1), MFP circuit board (MFPB)
(2) Step 1. Check whether the connector between FM1 and relay CN45-MFPB CN15E is correctly connected, and repair it if necessary. 2. Check whether the fan is overloaded and repair it if necessary 3. FM1 Operation Check Control Signal: MFPB CN15E-4(REM),MFPB CN15E-6(LOCK) Electrical Component Location: 17-C 4. Replace FM1 5. MFPB F7E Continuity Check 6. Replace MFPB
Fault analysis 1. According to the fault code handling guidelines in the maintenance manual, the C- 5370 code fault means that the power supply board cooling fan FM1 cannot rotate, and the parts involved are the power supply cooling fan FM1 and the MFP board. 2. The line connection between the MFP board and the power supply cooling fan FM1 is checked and it is normal. 3. The power supply cooling fan FM1 and the MFP board are replaced and tested, but the fault is not eliminated. 4, press the menu key on the operation panel, the machine does not respond and cannot perform any operation. 5. Try to clear the error by performing fault recovery. Press the recovery key to start the machine and enter the fault recovery interface, but press the recovery key and the screen does not respond. Check the status light on the operation panel, and find that the power key light is not on, and after the C- 5370 code is given, the operation panel keys cannot be operated and the machine cannot be operated.



Troubleshooting 1. Considering that the machine cannot be operated after the code is C- 5370 and the power button light on the operation panel is not on, the code cannot be eliminated by replacing the cooling fan FM1 and the MFP board test. Eliminate the faults of the cooling fan FM1 and the MFP board. Analyze that the power supply fault of the power board may cause the FM1 to fail to work. 2. Replace the power board test and the machine returns to normal.
√ If the cooling fan FM1 or MFP board failure causes the C- 5370 code failure, the power key light on the operation panel lights up in blue, and press the menu key to respond and enter the maintenance mode; √ If the power code is caused by the power board failure, the power key light does not light up, pressing the menu key does not respond and cannot enter the maintenance mode.


√ If the C- 5370 code fault is caused by the fault of cooling fan FM1 or MFP board, the power button light on the operation panel is bright blue, and fault recovery operation can be performed; √ If the C- 5370 code fault is caused by the fault of power board, the power button light on the operation panel is not bright, and fault recovery operation cannot be performed

For extended reference, the power supply board failure of bh287, C287 and C266 series models may lead to code failures such as "C-5370" and "C-40A1". These codes are not related to the power supply board in the maintenance manual. Please pay special attention to them during on-site processing.