Ricoh MP C306ZSP C406ZSP copier Chinese repair manual

Visitor 318 0
Ricoh MP C306ZSP C406ZSP copier Chinese maintenance manual+complete set of maintenance materials with attachments



Determine Vtref by developing gamma
By detecting the development gamma value through the ID sensor pattern and measuring Vsp/Vsg, the correct charging/development gamma for image density can be determined.
In addition, the TD sensor reading and development gamma can also determine Vtref, which is the reference value for the TD sensor.
LD power control
LD control is set through SP3-600-001 (process control/selection process control: LD control).
If SP 3-600-001 is set as LD power control through process control (default): LD intensity adjustment depends on the table determined by the developing bias and Vtref correction.
If SP 3-600-001 is set to use a fixed LD power, the LD power depends on
Settings for SP2-221-001/002/003/004.
Powder supply control
SP3-400-001, -002, -003, -004
0: Fixed powder supply method
2: PID method
4: DANC method (default)
Fixed powder supply method
The powder supply time is calculated based on the powder supply rates of SP3-440-001 to -004 (drive time: set).
• PID method
PID (Proportional Integral Derivative)
The powder supply is calculated based on pixel information and TD sensor information.