Solution of Xerox AP/DC-V C2275/3373 Error Indicator Light

Visitor 335 0
Model: Seito (AP/DC-V C2275/3373/3375/4475/5575/6675/7775)
Summary
Seito's machine, the second day after the opening of EPBB, the error light is always on
Content
On the day after EPBB is enabled, if the machine’s error light remains on continuously, there are typically two possible causes:
1. EP communication is not normal, and the communication failure prompt takes about 5 minutes to be displayed on the machine.
2. Turn off the power supply before the communication failure prompt appears, and EP communication still fails after 5 minutes after starting up again.
In the above case, the NVM920-093 will change (to a number other than 0 depending on the cause of communication failure). The machine error indicator will always be on and cannot be removed even if the NVM920-001(EP setting status) is changed to 0.
If the EP communication fails continuously for 24 hours, the NVM920-092 will change (a number other than 0 depending on the cause of the communication failure).
Solution
1. Check the NVM920-093. If it is not 0, change it to 0.
2. Check the NVM920-092. If it is not 0, change it to 0.
NVM 920-092, 920-093 refer to chapter 6 of the Seito Service Manual for the various meanings of the corresponding values.

Tags: #C2275 #c3375 #c4475 #c6675 #Error light always on