C754e,C654e Code C0104, C0105

Visitor 291 0
Fault Type Tray 3/4 Feeder Transfer Motor Cannot Rotate
Fault code C0104
Class B
During the detection of the sequential motor rotation, the lock signal is maintained at the high level for a predetermined continuous time interval.
Fault Isolation Tray 3/4
Associated Electrical Components • LCC Transfer Motor (M25)
• Feed/Transport Drive Circuit Board (PFTDB)
• Print Control Panel (PRCB)

Fault Type Tray 3/4 Feeder Transport Motor Rotation at Abnormal Timing
Fault code C0105
Class B
The lock signal is maintained at a low level for a predetermined continuous time interval during which the sequential motor is detected to be stationary. Fault Isolation-
Associated Electrical Components • LCC Transfer Motor (M25)
• Feed/Transport Drive Circuit Board (PFTDB)
• Print Control Panel (PRCB)


1 Check whether the connection of the connector between the M25-PFTDB CN17 is correct, and repair it if necessary.
2 Check M25 connector for correct drive coupling and repair if necessary.
3 M25 Operational Check PFTDB CN17-1 to 7 11-X
4 Replace M25 - -
5 PFTDB ICP6 Continuity Check--
6 Replace PFTDB - -
7 Replacing the PRCB