AP/DC-IV C5570/C4470/C3370/C2270 Summary: Users have reported that Kisyu's machine has color deviation in the copies when using the draft table for copying and DADF for copyingThe desktop copy is normal, but the DADF copy is slightly red (see attached figures 1 and 2). This situation also occurs during scanningIn the industry. The CSE repair process is as follows: upgrading firmware, performing MAX Setup adjustment, automatic color grading correctionExecuting NVM initialization, invalid. Replaced the scanning glass, exposure lamp, CCD component in sequence IIT Trans PWB, DADF components HDD、ESS PWB, It has also not been resolved. Content: The following NVM values of the faulty machine are not set correctly, causing the machine to color the file data abnormallyCompensation for color cast issues in photocopies and scanned documents.
Extraction code: k47m Principle analysis: NVM 715-097~099 are parameters used to compensate for the density of CVT scan imagesThe difference between NVM should not exceed 4. The color of file data tends to be biased towards parameters with larger values, only forCVT scanning is effective. In this case, R=112, which is much larger than G and B, so the copy is biased towards red.In addition to the above NVM, incorrect settings of NVM 715-092~094 can also cause color cast in replicas and affect CVTBoth scanning and manuscript scanning are valid. Unlike NVM 715-097~099, replicas tend to favor colors with higher valuesReverse color). DC945 in diagnostic mode: IIT calibration<白色参考调整>and During the initialization and scanning operations of IIT, the machine will light up the exposure light at the highlighted position, and the CCD willCalibrate the output based on the obtained white and black level data to ensure the accuracy of the file data obtained by IITExactly. Note: 1. Before executing DC945, please ensure that the MAX Setup project for the IOT section has been completed and the IOT output has been achievedCopy is normal 2. Execution<白色参考调整> Please make sure to correctly set the NVM 715-106 IIT paper code 3. NVM 715-097~099 is recorded in a random NVM Setting Value List after factory adjustment,On site changes can only be read/written through DC131: NVM, and cannot be performed in diagnostic mode on siteAdjust the project to make adjustments. (There is an issue with the adjustment values of the machine in this case when it leaves the factory) |
359
0
Address of this article:https://073868.com/post/5994.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleXerox C2270 Newly Installed 10-378 Code Solution
NextXerox (D95/110/125) cannot realize the printing electronic paging function