1) COPIER > OPTION > BODY > LOCALE (Set Target Group) [Settings] 1: Japan, 2: North America, 3: Korea, 4: China, 5: Taiwan, 6: Europe, 7: Asia, 8: Oceania 2) COPIER > OPTION > BODY > SIZE-LC (set paper size group) [SETTING] 1:AB series, 2: inch series, 3:A series, 4:AB/inch series 2. Clear Settings/Registration Data 1) COPIER > FUNCTION > CLEAR > ALL (Clear All Data) Once executed, the following data will be cleared according to the values of LOCALE and SIZE-LC set in step 1. • Set/register data (default values are set for each target). • Service mode data (default values are set for each target). • Job identification code • Log data • Date 2) COPIER > FUNCTION > CLEAR > R-CON (Clear the default setting value of reader/document feeder) 3. Adjust and input the default setting value 1) Turn off the automatic document feeder. 2) COPIER > FUNCTION > CCD> CL-AGC, BW-AGC (adjust white level) The white level is adjusted. 3) Enter the default setting value indicated on the service label in the corresponding service mode item. 4) COPIER > FUNCTION > VIFFNC > STOR-DCN (backup DC controller settings) Purpose: prepare for replacing the DC controller circuit board 5) Turn on the power after turning it off. 6) Start in initial installation mode. Follow the instructions displayed on the screen to set. Link: https://pan.baidu.com/s/1EvlywI3nX9wwGL9kyOIHSw提取码:1d1v |