Ricoh MPC8002SP,c6502 code fault SC374-04

Visitor 357 0
MPC8002SP user displays SC374-04.

1. On site testing shows that the printer can print when turned on, with normal black and white printing. However, the printed color is missing yellow. The 3210Y value is 2.91, and the 3630Y value is around 1.2 The value did not change after the forced addition of powder.
2. Clean the ID sensor and manually fill it with yellow toner. Still lacking color. The process control for 3-011 was unsuccessful.
3. After backing up the 5-824 data and performing 3-030K Y initialization, SC670 unexpectedly jumped.
4. After disconnecting the hard drive and reinserting the memory, which was ineffective, I opened the drawer unit to import the previously backed up values and was able to print again, but still lacked yellow color.
5. There are many fault codes for 7-403. Currently, there is still a lack of color. May I ask how to handle the inspection? During on-site inspection, the VT and gamma values were close to normal.



Maintenance guidance:
1. It is recommended to carefully check whether the yellow transfer roller in the image transfer unit (ITB) has fallen off or has poor contact, resulting in a low gamma value for yellow. If possible, the ITB unit can be exchanged for testing. In addition, poor transfer high-pressure plate may also cause the above fault phenomena.

2. Is there any powder in the developing chamber? If there is powder, your image is color deficientThat should have nothing to do with the powder concentration. The 496 and 374 codes both have ID data errors, and it is suspected that the image did not reach the transfer belt at all. I feel that the probability of laser and IPU board failures is relatively high.

3. Check the development, the magnetic roller is also normal, and inspect the circuit board inside the transfer belt, which has a lot of toner on it. Transfer the entire transfer unit to another machine for testing, and the yellow color is normal. After reinstalling the machine for testing, it was found that the yellow color could be printed out, but the color was relatively light. It was suspected that it was caused by poor contact, and the high-voltage plate of the transfer unit may also have caused this fault.

Tags: #374-04 #6502 #8002 #Yellow #Transfer printing